Whether your application is high-volume in situ production, incoming inspection and validation, or just basic force measurement, the L2 System is an economical and easy-to-use solution. L2 Systems feature a small footprint making them ideal for lean manufacturing environments. Create test setups in seconds using templates or create complex multi-stage test setups using the L2 Test Builder.
No programming experience required.
L2 Systems operate using a Windows®-based tablet PC. Load, distance and time based results are displayed in a large format for easy interpretation.
Graphical representation of each test can be displayed. Data tables display results with tolerance and statistical calculations. Standard reports are included, or export data for use with other applications. System capacities range from 500N (112lbf) to 50kN (11,250lbf).
The Starrett L2 system features a tablet computer featuring a 10-inch (254mm) colour, touchscreen display. The system is WiFi®, Bluetooth® and USB compatible. Perform common test methods such as determining maximum load, maximum deflection, average loads or how product reacts when a constant load is applied for a specified period of time. L2 systems can determine break strengths and the sample's characteristics at load and extension limit values and provide you with immediate pass/fail indication.
View our range of Load Cell Sensors
Features |
|
Model Number |
|
FMS-500 | FMS-1000 | FMS-2500 | FMS-5000 | FMD-10K | FMD-30K | FMD-50K |
Load Capacity |
N
kgf lbf |
500
50 112 |
1000
100 225 |
2500
250 562 |
5000
500 1124 |
10,000
1000 2250 |
30,000
3000 6750 |
50,000
5000 11,250 |
Minimum Speed |
mm/min
in/min |
0.05
0.002 |
0.05
0.002 |
0.05
0.002 |
0.05
0.002 |
0.05
0.002 |
0.05
0.002 |
0.05
0.002 |
Maximum Speed |
mm/min
in/min |
1525
60 |
1525
60 |
1525
60 |
1525
60 |
1525
60 |
1525
60 |
752
30 |
Position Control Resolution |
μm
μin |
0.250
9.8 |
0.250
9.8 |
0.250
9.8 |
0.250
9.8 |
0.05
1.9 |
0.025
0.9 |
0.025
0.9 |
Vertical Test Space1 |
mm
in |
559
22 |
953
37.5 |
1257
49.5 |
1257
49.5 |
1270
50 |
1245
49 |
1220
48 |
Total Crosshead Travel |
mm
in |
381
15 |
762
30 |
1016
40 |
1016
40 |
1162
47.5 |
1137
44.75 |
1111
43.75 |
Throat |
mm
in |
100
4 |
100
4 |
100
4 |
100
4 |
424
16.7 |
424
16.7 |
424
16.7 |
Accuracy Load Measurement | Load Cell Censor Dependent | |||||||
Accuracy Position Measurement2 |
±0.001inch (±20 μm) | |||||||
Accuracy Crosshead Speed |
±0.1% of set speed | |||||||
Data Sampling | Hz | 5 to 1000 | ||||||
Digital I/O | 8 channels @ 1-5V | |||||||
Electrical Phase | 1 | |||||||
Power Requirements |
100, 120, 220, 230, 240VAC 10%; 47-63Hz Self-identifying |
100, 120, 220,
230, 240Vac 10% |
Single Phase
Voltage (Vac) ±10% 220-240V |
Single Phase
Voltage (Vac) ±10% 220-240V |
||||
Operating Temperature |
°C
°F |
+10° to +38°C
+50° to 100°F |
||||||
Storage Temperature |
°C
°F |
-40° to +66°C
-40° to 150°F |
||||||
Humidity | +10% to +90%, non-condensing | |||||||
Total Height |
mm
in |
805 31.7 |
1218 47.9 |
1573 61.9 |
1573 61.9 |
1685 66.4 |
1711 67.4 |
1711 67.4 |
Total Width |
mm
in |
381 15 |
381 15 |
381 15 |
381 15 |
787 31 |
787 31 |
787 31 |
Total Depth |
mm
in |
514 20.3 |
514 20.3 |
514 20.3 |
514 20.3 |
724 28.5 |
724 28.5 |
724 28.5 |
Weight |
kg
lb |
61 135 |
77 170 |
88 195 |
88 195 |
136 300 |
192 425 |
225 500 |